Windows Server 2008
- Specifies an expanded string data value. The environment variable specified in the string must exist for the string to be ...
- Specifies attributes of the LUID. This value contains two 32-bit flags. Its meaning is dependent on the definition and use ...
- Specifies attributes of the SID. This value contains up to 32 one-bit flags. Its meaning depends on the definition and use ...
- Specifies if the units returned by this Sensor are rate units. All the values returned by this Sensor are represented in ...
- Specifies provider-specific data. Applications should ignore this member unless they have detailed information about the ...
- Specifies that Access-Request packets are signed to prevent dictionary attacks on CHAP, ARAP, or EAP authentication methods. ...
- Specifies that the Ascend NAS use only the 56-Kbps portion of a channel (even when the full 64 Kbps channel is available ...
- Specifies that the Ascend PPP implementation must not use slot compression when sending packets that are compressed through ...
- Specifies that the password is encrypted when passed between the RADIUS server and the Ascend NAS. This attribute is used ...
- Specifies that this attribute is included in an Accounting-Request packet to record the time that a specific event occurred ...
- Specifies that Windows authorization is enabled for users authenticated by the remote RADIUS server (for example, use with ...
- Specifies the active process limit for the job. If you try to associate a process with a job, and this causes the active ...
- Specifies the address of the last memory error. The type of error is described by the ErrorInfo property. If the ErrorInfo ...
- Specifies the async control character map that the Ascend PPP implementation must use during the PPP session (Ascend NAS ...
- Specifies the Audit Permissions for failure. The permissions are a combination of one or more of the following:WINSTATION_QUERY, ...
- Specifies the Audit Permissions for success. The permissions are a combination of one or more of the following:WINSTATION_QUERY, ...
- Specifies the certificate purpose or usage object identifiers (OIDs), in dotted decimal notation, that are allowed for when ...
- Specifies the connection profile, through which the home agent sends packets that are received by a mobile node in ATMP operation. ...
- Specifies the current character set being used for the output of text relating to management of the Printer. The character ...
- Specifies the DCE-monitored event count. A link is considered active if the value of the Ascend-FR-DCE-N393 attribute is ...
- Specifies the default mime type used by the Printer if the DefaultLanguage is set to indicate a mime type is in use (value=47). ...
- Specifies the disk allocation unit size or cluster size. All file systems used by this version of Windows organize your hard ...
- Specifies the DTE-monitored event count. A link is considered active if the value of the Ascend-FR-DTE-N393 attribute is ...
- Specifies the Dynamic Bandwidth Allocation (DBA) algorithm used for calculating the average line utilization (ALU) for transmitted ...
- Specifies the encoding of Extensible Authentication Protocol (EAP) information to allow dial-in users to use EAP to authenticate ...
- Specifies the IP traffic filter that is used by the Routing and Remote Access service when the connection is in a restricted ...
- Specifies the largest Job (as a byte stream) that the Printer will accept in units of Kbytes. A value of zero indicates that ...
- Specifies the length of time (in minutes) for which a cached token can remain alive between authentications if a call is ...
- Specifies the length of time (in seconds) between the time that a call connects and the time that authentication is complete. ...
- Specifies the length of time (in seconds) that a terminal server connection must be idle before the Ascend NAS disconnects ...
- Specifies the length of time (in seconds) that the Ascend NAS uses as a sample for calculating the average line utilization ...
- Specifies the link management protocol that is used between the Ascend NAS and the Frame Relay switch in a Frame Relay profile. ...
- Specifies the maximum allowable baud rate, in bits per second (bps). This member can be one of the following values: Value ...
- Specifies the maximum size, in bytes, of the driver's internal input buffer. A value of zero indicates that no maximum value ...
- Specifies the maximum size, in bytes, of the driver's internal output buffer. A value of zero indicates that no maximum value ...
- Specifies the maximum working set size for all processes associated with the job. Ignored unless LimitFlags specifies Limit ...
- Specifies the method that RADIUS uses to handle passwords that received from users who are required to use a hand-held security ...
- Specifies the mime type currently being used by the Printer if the CurrentLanguage is set to indicate a mime type is in use ...
- Specifies the minimum working set size for all processes associated with the job. Ignored unless LimitFlags specifies Limit ...
- Specifies the named value to be deleted from the subkey. Specify an empty string to delete the default named value (the default ...
- Specifies the named value to be deleted from the subkey. Specify an empty string to delete the default named value (the default ...
- Specifies the named value whose data value you are setting. You can specify an existing named value (update) or a new named ...
- Specifies the number of bytes read by all processes that have ever been associated with the job, in addition to all processes ...
- Specifies the number of bytes transferred during operations, other than read and write operations, by all processes that ...
- Specifies the number of bytes written by all processes that have ever been associated with the job, in addition to all processes ...
- Specifies the number of channels that the Ascend NAS adds when bandwidth changes either manually or automatically during ...
- Specifies the number of errors that occurred during Ascend-FR-DCE-N393-monitored events, causing the network to render user-originating ...
- Specifies the number of errors that occurred during Ascend-FR-DTE-N393-monitored events, causing the user to render the network-originating ...
- Specifies the number of I/O operations performed, other than read and write operations, by all processes that have ever been ...
- Specifies the number of idle seconds that the Ascend NAS waits before using one of the channels of an idle link for a new ...
- Specifies the number of read operations performed by all processes that have ever been associated with the job, in addition ...
- Specifies the number of sessions that remain in a Multilink bundle (multichannel Multilink Protocol or Multilink Protocol ...
- Specifies the number of write operations performed by all processes that have ever been associated with the job, in addition ...
- Specifies the paper type that the Printer is currently using. The string should be expressed in the form specified by ISO/IEC ...
- Specifies the paper type that the Printer will use if a PrintJob does not specify a particular type. The string should be ...
- Specifies the per-job memory limit in kilobytes. It is ignored unless the LimitFlags specifies the Limit Job Memory value. ...
- Specifies the per-job user-mode execution time limit, in 100 nanoseconds. The system adds the current time of the processes ...
- Specifies the per-process memory limit in kilobytes. It is ignored unless the LimitFlags specifies the Limit Process Memory. ...
- Specifies the per-process user-mode execution time limit, in 100 nanoseconds. It is ignored unless LimitFlags specifies Limit ...
- Specifies the percentage of bandwidth utilization, below which the Ascend NAS clears a single-channel Multilink Protocol ...
- Specifies the Permissions that are allowed. The permissions are a combination of one or more of the following:WINSTATION_QUERY, ...
- Specifies the Permissions that to be allowed. The permissions are a combination of one ore more of the following:WINSTATION_QUERY, ...
- Specifies the position of the physical memory in a 'row'. For example, if it takes two 8-bit memory devices to form a 16-bit ...
- Specifies the presence of a Data Link Connection Identifier (DLCI) for the user profile in a Frame Relay redirect connection. ...
- Specifies the priority class for all processes associated with the job. Processes and threads cannot modify their priority ...
- Specifies the processor affinity for all processes associated with the job. The affinity of each thread is set to this value, ...
- Specifies the protocol used for name-password authentication (following Called Link Identification CLID authentication). ...
- Specifies the range, in bytes, to which the last error can be resolved. For example, if error addresses are resolved to bit ...
- Specifies the relative preference assigned to each tunnel when more than one set of tunneling attributes is returned to the ...
- Specifies the scheduling class for all processes associated with the job. The valid values are 0 to 9. Use 0 for the least ...
- Specifies the security limitations for the job.A value of No Administrator prevents any process in the job from using a token ...
- Specifies the size, in bytes, of the driver's internal input buffer. A value of zero indicates that the value is unavailable. ...
- Specifies the size, in bytes, of the driver's internal output buffer. A value of zero indicates that the value is unavailable. ...
- Specifies the threshold, in seconds, that the average line utilization (ALU) for transmitted data must exceed before the ...
- Specifies the threshold, in seconds, that the average line utilization (ALU) for transmitted data must fall below before ...