To set the default pull partner parameters for the WINS server. Syntax: set pullparam State=]0|1 Strtup=]1|0 Start=]Value ...

To set the default pull partner parameters for the WINS server. 
 
Syntax: 
 
        set pullparam [State=]0|1  [[Strtup=]1|0] [[Start=]Value] 
        [[Interval=]Value] [[Retry=]Value] 
 
Parameters: 
 
        State          - 0-Do not use persistent connections with pull 
                         partners.  
                         1-Use persistent connections with pull partners. 
 
        Strtup         - 0-Do not start pull replication at startup 
                         (default).  
                         1-Start pull replication at startup. 
 
        Start          - Start time for the pull trigger (seconds). 
 
        Interval       - Replication interval (seconds). 
 
        Retry          - Retry count. 
 
Note:          None of these parameters are required and, when not 
               used, previously set or default values are maintained. 
 
Example:       set pullparam state=1 strtup=1 start=23600 interval=259200 
                             retry=7 
 
               This command sets the default pull partner parameters 
               for this WINS server to use a persistent connection 
               with its pull partners, begin replication at startup, 
               start the pull trigger in 23600 seconds at an interval 
               of 259200 seconds, and retry replication seven times.